500L/H Ro Systems RO Pure Water Treatment Filtration Purification Reverse Osmosis System

Benvenuti su WhatsApp

500L/H Ro Systems RO Pure Water Treatment Filtratification Reverse Osmosis System Manufacturers

Commercial reverse osmosis water purification systems are used to purify water. The system is controlled by raw water pump, FRP/stainless steel pretreatment tank (sand filter, activated carbon filter), SS304 cartridge security filter housing, chemical dosing system, high pressure pump, FRP membrane pressure vessel, 4040 membrane, control panel and touch screen composition. RO Pure Water Treatment  
Get A Quote
sprite

Opis proizvoda

Reverse osmosis is the most precise membrane liquid separation technology. The operating pressure is applied on the side of the inlet water and the concentrated solution to overcome the natural osmotic pressure. 
When the operating pressure higher than the natural osmotic pressure is dropped on the side of the concentrated solution water molecules naturally permeate the flow The direction will be reversed, and the water molecules in the influent concentrated solution pass through the reverse osmosis membrane to become the purified water om the dilute solution side Reverse osmosis suitable equipment can block all soluble salts and organic substances with a molecular weight greater than 100. but allow water molecules to pass through, The salt rejection rate of reverse osmosis composite membranes is generally greater than 98%.
 
 
500LH Ro Systems RO Pure Water Treatment Filtration Purification 5
Most of our projects use DOW Filmtec, Toray, Vontron, Hydranautics, LG brands. They are well-known brands in the water treatment industry.

The reverse osmosis membrane is the core element to realize reverse osmosis, and it is an artificial semipermeable membrane with certain characteristics made by simulating biological semipermeable membrane. Generally made of polymer materials. Such as cellulose acetate film, aromatic polyhydrazide film, aromatic polyamide film. The diameter of the surface pores is generally between 0.5 and 10 nm, and the permeability is related to the chemical structure of the membrane itself. Some polymer materials have good repellency to salt, but the permeation speed of water is not good. The chemical structure of some polymer materials has more hydrophilic groups, so the permeation speed of water is relatively fast. Therefore, a satisfactory reverse osmosis membrane should have an appropriate amount of permeation or salt rejection.

Additionally, commercial RO water treatment systems can incorporate chemicals such as anti-scaling (scaling inhibitors), anti-fouling, pH adjustment, sterilization and disinfection chemicals in the pre- or post-treatment. We keep a close eye on the water treatment industry and add new water technologies to our reverse osmosis water plants.

When checking the customer's water quality analysis report, sometimes due to scaling and scaling problems, we can use the CIP (cleaning-in-place) system to clean the membrane in the membrane shell to make the membrane longer life. It is a new type of water treatment technology most used in the water treatment industry.

Električna energija komercijalnih RO sistema za prečišćavanje vode

Za komercijalno prečišćavanje vode potrebno je 220-380V/50Hz/60Hz. Za veći kapacitet, posebno za industrijski sistem reverzne osmoze, zbog pumpe visokog pritiska, potrebno je 380V 50/60Hz. Što se tiče vašeg komercijalnog dizajna mašine za filtriranje vode u reverznoj osmozi, proverićemo vaše električno napajanje i odlučiti da popravimo napajanje za vas. Takođe, imamo neke metode uštede energije za smanjenje troškova električne energije, Chunke nove tehnologije za prečišćavanje vode pomažu vam da smanjite svoje najveće troškove za pokretanje sistema.

Pre kupovine komercijalnog sistema za prečišćavanje vode, trebalo bi da znate:

1. kapacitet proizvodnje čiste vode (L/dan, L/sat, GPD).

2. Feed Water TDS i Raw Water Analysis Report (sprečavanje problema sa fauliranjem i skaliranjem)

Gvožđe i mangan se moraju ukloniti pre nego što sirova voda uđe u membranu za filtriranje vode reverzne osmoze.

TSS (Total Suspended Solid) se mora ukloniti pre membrana komercijalnog sistema za prečišćavanje vode.

SDI (indeks gustoće mulja) mora biti manji od 3

Morate biti sigurni da vaš izvor vode nema ulja i masti

Hlor se mora ukloniti pre komercijalnog sistema za prečišćavanje vode

8. raspoloživi napon električne energije i faza

9. Raspored mjesta za komercijalni ro sistem reverzne osmozeSpecifikacija rada za komercijalne RO sisteme za prečišćavanje vode   

Feed Water TDS: 0 - 1000ppm

Tvrdoća preko 18 ppm Potrebna antiskalantna doza

Zamućenost mora biti

 Ukloniti

Max. temperatura vode za hranu: 42°C

Rad na višim TDS rezultatima niže

 Oporavak

H2S mora da bude

 Ukloniti

pH tolerancija: 3-11

Max. sadržaj željeza: 0,05ppm

 

Pritisak vode: 1,5 do 6 bar

Max. Tolerancija silicijuma: 60ppm

 

Contact us to learn more about our industrial reverse osmosis systems and commercial RO water plants. Our sales team and technical team will be happy to share new water treatment technologies for your project.
 RO tretman čiste vode
 
sprite

Parametar proizvoda

STK-RO-500L technical parameter

Productivity:0.5T/H
Motor power:1.5kw
Recovery rate:90% 
Qutlet water conductivity:≦10 μs/cm 
Raw water conductivity:≦300 μs/cm 
 
500LH Ro Systems RO Pure Water Treatment Filtration Purification 3
sprite

Primjenjiva industrija

They are widely used in the preparation of industrial pure water and electronic ultra-pure water for drinking, In the process of pure water production and boiler feed water, the use of reverse purification equipment before ion exchange can greatly reduce the discharge of operating water and waste water.
starkwater

Preporučeni proizvodi

Postavljajte pitanja.