RO Pure Water Treatment is the most precise membrane liquid separation technology. The operating pressure is applied on the side of the inlet water and the concentrated solution to overcome the natural osmotic pressure.
When the operating pressure higher than the natural osmotic pressure is dropped on the side of the concentrated solution water molecules naturally permeate the flow The direction will be reversed, and the water molecules in the influent concentrated solution pass through the reverse osmosis membrane to become the purified water om the dilute solution side Reverse osmosis suitable equipment can block all soluble salts and organic substances with a molecular weight greater than 100. but allow water molecules to pass through, The salt rejection rate of reverse osmosis composite membranes is generally greater than 98%.
RO tretman čiste vode
Most of our projects use DOW Filmtec, Toray, Vontron, Hydranautics, LG brands. They are well-known brands in the water treatment industry.
The reverse osmosis membrane is the core element to realize reverse osmosis, and it is an artificial semipermeable membrane with certain characteristics made by simulating biological semipermeable membrane. Generally made of polymer materials. Such as cellulose acetate film, aromatic polyhydrazide film, aromatic polyamide film. The diameter of the surface pores is generally between 0.5 and 10 nm, and the permeability is related to the chemical structure of the membrane itself. Some polymer materials have good repellency to salt, but the permeation speed of water is not good. The chemical structure of some polymer materials has more hydrophilic groups, so the permeation speed of water is relatively fast. Therefore, a satisfactory reverse osmosis membrane should have an appropriate amount of permeation or salt rejection.
Additionally, commercial RO water treatment systems can incorporate chemicals such as anti-scaling (scaling inhibitors), anti-fouling, pH adjustment, sterilization and disinfection chemicals in the pre- or post-treatment. We keep a close eye on the water treatment industry and add new water technologies to our reverse osmosis water plants.
When checking the customer's water quality analysis report, sometimes due to scaling and scaling problems, we can use the CIP (cleaning-in-place) system to clean the membrane in the membrane shell to make the membrane longer life. It is a new type of water treatment technology most used in the water treatment industry.
Električna energija komercijalnih RO sistema za prečišćavanje vode
Za komercijalno prečišćavanje vode potrebno je 220-380V/50Hz/60Hz. Za veći kapacitet, posebno za industrijski sistem reverzne osmoze, zbog pumpe visokog pritiska, potrebno je 380V 50/60Hz. Što se tiče vašeg komercijalnog dizajna mašine za filtriranje vode u reverznoj osmozi, proverićemo vaše električno napajanje i odlučiti da popravimo napajanje za vas. Takođe, imamo neke metode uštede energije za smanjenje troškova električne energije, Chunke nove tehnologije za prečišćavanje vode pomažu vam da smanjite svoje najveće troškove za pokretanje sistema.
Pre kupovine komercijalnog sistema za prečišćavanje vode, trebalo bi da znate:
1. kapacitet proizvodnje čiste vode (L/dan, L/sat, GPD).
2. Feed Water TDS i Raw Water Analysis Report (sprečavanje problema sa fauliranjem i skaliranjem)
Gvožđe i mangan se moraju ukloniti pre nego što sirova voda uđe u membranu za filtriranje vode reverzne osmoze.
TSS (Total Suspended Solid) se mora ukloniti pre membrana komercijalnog sistema za prečišćavanje vode.
SDI (indeks gustoće mulja) mora biti manji od 3
Morate biti sigurni da vaš izvor vode nema ulja i masti
Hlor se mora ukloniti pre komercijalnog sistema za prečišćavanje vode
8. raspoloživi napon električne energije i faza
9. Raspored mjesta za komercijalni ro sistem reverzne osmozeSpecifikacija rada za komercijalne RO sisteme za prečišćavanje vode
Feed Water TDS: 0 - 1000ppm |
Tvrdoća preko 18 ppm Potrebna antiskalantna doza
|
Zamućenost mora biti
Ukloniti
|
Max. temperatura vode za hranu: 42°C
|
Rad na višim TDS rezultatima niže
Oporavak
|
H2S mora da bude
Ukloniti
|
pH tolerancija: 3-11
|
Max. sadržaj željeza: 0,05ppm
|
|
Pritisak vode: 1,5 do 6 bar
|
Max. Tolerancija silicijuma: 60ppm
|
|
Contact us to learn more about our industrial reverse osmosis systems and commercial RO water plants. Our sales team and technical team will be happy to share new water treatment technologies for your project.